Motor capacitor run basic operation is same with motor capacitor start that use a capacitor to generate the current pulse and create the electromagnetic field for the winding to push a rotor to turn around.
Normally capacitor for this motor made from polypropylene film capacitors material and it can running continuous without any problem.Run capacitor rated from 2 μf until 100 μf with nominal single phase voltage 110 VAC,240 VAC and 440 VAC.
If we installed the capacitor with wrong wiring termination,it’s can’t generated the electromagnetic field and motor not running.We can recognize this symptom if motor create a noising sound and it’s can make a motor drop the performance and more serious can cause the winding damage.
Permanent Split Capacitor or PSC
It has a running coil and capacitors are mounted a series of motion at all times.It is usually used for Primarily a fan and blower motor and Very low cost motor.
Motor operation
- Capacitor in “Capacitor Winding”
– Provides a “phase shift” for starting.
– Optimizes running characteristics.
- No centrifugal switch